Site Inspection Form-View

Date
  03/09/2026
Builder\Owner
  Westin Homes. Josh
Phone
  (832) 692-3467
Address
  10803 Starry Farm Way
United States
Map It
Sub division
  Candela
Email
  rbolten@hoelscherdoor.com
Inspected By
  Roger Bolten
Copy on Email
 
  • Roxanne Butschek
Notes
  Front Door not Latching and Back Door w/s.

Front Door. 3080 R/H I/S
Door has a gap at the latch and some times doesn’t latch. See pic
Inside jamb width
Top 36 1/8
Middle 36 1/8
Bottom 36
Door is 35 3/4
Door was over planed and the mortise on the latch is too deep. See pic.
Hinge side has a 1/8 revile and strike side has a 1/4 revile.

Back Door 2880 L/H I/S
Strike side p/f w/s is cut 1” too short

AAP. Remove H/W and shime behind the throw to get it flush with doors edge.
Spread hinges to even out the revile on both sides.
Back Door replace strike side w/s.

AAP #2. Re-block strike side jamb leg. But to do so we would have to cut the header back.