Interior study D/D 2/6 x 8/0, has only one bolt at top told homeowner that it is normal for
an interior D/D to have only one bolt at top.
Master-S/D 2/0 x 8/0 was complaining about air coming in around locks, the air was
coming in through the lock holes in the jamb. This door has a storm door. The
storm door expander is not sealing to Sillcover on one side and is missing one of
rubber sweeps. Need to add corner pads on jamb and adjust door Expander to sill
on top of Sillcover and install the other rubber sweep that goes on the storm door
expander. ( once door expander is adjusted there will be a visible hole in the storm
door) WARRANTY, CALL HOMEOWNERS TO SCHEDULE Senties 346-574-9777
See pics
Dining-D/D 2/6 x 8/0 Sq Top, Neulite, Fulllite Flush Glaze, homeowner wants price for
Neulite Flush Glaze with mini blind insert. We installed door unit 2-12-24. Homeowner
Closed August of 2024. All of his back doors have mini blind inserts except for dining
Could we see what was ordered through Partners in Building.
Homeowners Email fsenties@amitia.com