Sales Person
|
| |
Josh
|
|
Site Inspector
|
| |
Craig Graves
|
|
Date
|
| |
02/27/2026
|
|
Address
|
| |
208 Whitehall Ln United States Map It
|
|
Zip Code
|
| |
77546 United States Map It
|
|
Contact
|
| |
Gary Decosmo
|
|
Phone
|
| |
(832) 723-0476
|
|
Builder
|
| |
Gulf Coast Restoration
|
|
Phone
|
| |
832 723-0476
|
|
Email
|
| |
cgraves@hoelscherdoors.com
|
|
Opening Location
|
| |
Front , new jamb , reuse existing door panel
|
|
Height
|
| |
9’
|
|
Depth
|
| |
8’
|
|
Direction Facing
|
| |
South
|
|
|
Door Width
|
| |
3/6
|
|
Height
|
| |
6/8
|
|
Thickness
|
| |
1-3/4”
|
|
Door
|
| |
|
|
Door Type
|
| |
Wood painted , reuse door
|
|
Door Width
|
| |
42”
|
|
Height
|
| |
79-1/8”
|
|
Other
|
| |
Vinyl Btm
|
|
T/H Height
|
| |
1-1/4”
|
|
Frame Specs – Jamb Depth
|
| |
4-9/16”
|
|
Inside Unit Width
|
| |
42-1/4”
|
|
To under Header Rabbet
|
| |
80-1/2”
|
|
Type of Finished Floor
|
| |
Vinyl
|
|
Floor height above slab (approx)
|
| |
3/4”
|
|
New Jamb Leg Length
|
| |
81-1/4”
|
|
Still Pan Present on wood subfloor
|
| |
Yes
|
|
Subsill Length
|
| |
46” x 3/4”
|
|
Depth
|
| |
4”
|
|
Casing: Exterior
|
| |
|
|
Notes
|
| |
Builder will remove and install new
|
|
Interior Width
|
| |
Builder will remove and install new
|
|
Type
|
| |
Builder to remove and install new
|
|
T/H & W/S SPECS:
|
| |
43” 129A
SC 43” x 3” x 3/4”
101 expander 43” x 2” x 1-3/4”, being used to eliminate high TH ( per Builder)
3 Square aluminum hinges , see photo
Prefab w/s
Subsill 46” x 4” x 3/4”
Remove 2 x 4 and add new Subsill
Remove existing unit , jambs and door panel
PAINT GRADE JAMB
Painting to be done by Builder
|
|
CUSTOMER SELECTIONS
|
| |
Builder wants new jamb but reusing existing door
Builder will install new interior casing
Builder will install new exterior 1 x 4 , caulk and paint
Builder will remove interior casing , and BM , plus cut back siding to allow new jamb to fit
Paint to be done by Builder
|
|
Additional Notes and Instructions
|
| |
Reusing existing door
Remove 2 x 4 under existing TH and add 3/4” material
Builder to remove interior casing , BM and cut siding back to allow new jamb to fit
All painting to be done by Builder
|
| Jamb Kit Order |
|
Contractor
|
| |
Gulf Coast Restoration
|
|
Contractor Phone
|
| |
832 723-0476
|
|
Owner
|
| |
Gary Decosmo
|
|
Owner Phone
|
| |
832 723-0476
|
|
Job Address
|
| |
208 Whitehall Ln ( loc near brandywynne Dr)
|
|
Description
|
| |
Reuse existing door , front door, 42” x 79-1/8” x 1-3/4”, mortise hinges on site
|
|
Untitled
|
| |
|
|
Door Notes
|
| |
Reuse existing door
|
|
Jamb Kit
|
| |
|
|
Notes
|
| |
Reuse existing door
Provide new jamb legs and header
Remove 2x 4 Subsill
Add new subsill 46” x 4” x 3/4”
101 expander is being used to eliminate high TH
|
| Components |
|
# of Pcs
|
| |
3
|
|
Jamb Legs (H)
|
| |
2-81-1/4”x 4-9/16”
|
|
(Depth) Header
|
| |
1- 42-1/4” x 4-9/16”
|
|
# of Pcs
|
| |
1
|
|
Subsil (L)
|
| |
46” x 3/4”
|
|
(Depth)
|
| |
4”
|
|
1×4 Length
|
| |
No
|
|
Brickmold (Length)
|
| |
No
|
|
Casing-Type
|
| |
No
|
|
Copy on Email
|
| |
- Joshua Howell
- Craig Graves
|
Recent Comments